Short answer: an EICR must be carried out by a “qualified and competent person”. The law does not say NICEIC, NAPIT or any other scheme by name — but in practice a London landlord, letting agent, licensing officer or insurer will expect the report to come from an electrician registered with a government-approved competent person scheme, holding a current inspection and testing qualification (City & Guilds 2391 or equivalent), with calibrated test instruments and public liability insurance. F & A Electrical is NICEIC registered and every EICR we issue is from £140 labour-only. Here is exactly what the rules say and what to check before you book anyone.
What the regulations actually require
The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require the inspection and testing to be done by a “qualified person” — defined as someone “competent to undertake the inspection and testing required… and any further investigative or remedial work”. The government’s own guidance for landlords then explains how to judge competence: the electrician should be a member of a competent person scheme, or be able to demonstrate qualification and experience if they are not. That is the whole legal position. There is no register of “EICR-approved” individuals and no licence specific to EICRs.
What that means in practice is that the responsibility sits with the landlord to pick someone competent. If the report turns out to be worthless — a driveway “visual” done in twenty minutes with no test results — it is the landlord facing the up-to-£40,000 civil penalty under the Renters’ Rights Act since 1 May 2026, not the person who signed it.
Who counts as competent — the 5-point check
| Check | What to ask for | Why it matters |
|---|---|---|
| 1. Scheme registration | NICEIC, NAPIT, ELECSA/Certsure or STROMA registration number — verify on the scheme’s online register | Schemes assess the business annually, including its inspection and testing work |
| 2. Inspection & testing qualification | City & Guilds 2391-52 (or older 2391-10/20, 2394/2395), EAL equivalent | This is the qualification specifically for periodic inspection — a wiring-regs (2382) certificate alone is not enough |
| 3. BS 7671 current edition | 18th Edition Amendment 2 (2382-22) | The report’s C1/C2/C3 codes are judged against the current edition |
| 4. Calibrated instruments | Calibration certificate for the multifunction tester, dated within 12 months | Zs, insulation resistance and RCD trip times mean nothing from an uncalibrated meter |
| 5. Insurance | Public liability (£2m+ typical) and ideally professional indemnity | Lenders, agents and licensing schemes ask for it |
Does it have to be NICEIC?
No. NICEIC is the largest scheme and the one most agents recognise, which is why the NICEIC logo tends to be treated as shorthand for “proper electrician” — but NAPIT, ELECSA and STROMA registrations are equally valid for an EICR, and a non-registered electrician who can prove the 2391 qualification and calibrated kit is legally acceptable too. What you should be wary of is the reverse: a company using a scheme logo on its website when the person who turns up is not the registered individual, or a “£59 EICR” that is only viable because no actual testing happens. You can check any NICEIC number at niceic.com/find-a-tradesperson; ours is shown on every certificate.
Can I do my own EICR?
If you are the landlord, no — even if you are an electrician, a report on your own rental property is not independent and will not satisfy a licensing officer or insurer. If you are simply a competent homeowner, also no: an EICR is not a visual inspection but a set of dead and live tests (continuity, insulation resistance, earth fault loop impedance, RCD operation) that require the tester, the training and the experience to interpret the results. A tenant cannot commission one on your behalf either, though they can request one via the council.
Who cannot sign an EICR
- A general handyman or “electrical installer” without inspection and testing training
- A gas engineer who also “does electrics”
- An apprentice or improver signing in their own name
- A firm that subcontracts the visit to an unregistered individual and signs with the firm’s scheme number — the person who tests must be the competent person
- Anyone issuing a “certificate” without the schedule of test results attached — an EICR without test results is not an EICR
What a genuine EICR looks like
A proper report runs to several pages: the property and installation details, the extent and limitations agreed with you, the schedule of inspections, the schedule of circuit details and test results (every circuit, with measured values, not ticks), the observations coded C1, C2, C3 or FI, and an overall assessment of Satisfactory or Unsatisfactory. Our C1/C2/C3 codes guide explains the observation codes and our unsatisfactory EICR guide covers the 28-day remedial clock. If you have been handed a one-page “pass” with no test results, treat it as if you had nothing.
What we charge
| Property | Price (labour-only, ex materials) |
|---|---|
| Flat or small house (up to ~8 circuits) | from £140 |
| Large house or HMO | from £180 — HMO EICR guide |
| Remedial work for C1/C2 items | from £108 — remedial cost guide |
| Same-day or next-day slot | no premium — same-day EICRs |
Full 2026 pricing and what drives it is in our London EICR cost guide. We cover Hackney, Islington, Camden, Tower Hamlets, Haringey and the rest of inner north and east London from our Tottenham base — see all service areas.
Frequently asked questions
Is an EICR from a non-NICEIC electrician valid?
Yes, provided the electrician is competent — qualified in inspection and testing, using calibrated instruments and able to show it. Scheme membership is the easiest way to prove competence, not a legal requirement in itself.
Does the electrician need to be Part P registered to do an EICR?
Not strictly. Part P registration is about self-certifying notifiable installation work under the Building Regulations; an EICR is inspection, not installation. But any remedial work that follows — a new consumer unit, a new circuit — is notifiable, so using a registered electrician for both avoids a second visit and a Building Control fee.
Can a letting agent insist on their own electrician?
They can recommend, but the report only has to be from a competent person. If the agent’s contractor is quoting a lot more than the £140–£180 range, you are entitled to use your own electrician and the agent must accept a valid report.
How do I check an NICEIC number?
Search the business name or number on the NICEIC “find a tradesperson” register. The registered address and trading name should match the certificate. If they don’t, ask why before you pay.
Related: landlord EICRs in London, EICR fines explained, EIC vs EICR, landlord compliance checklist.